We would like to inform you that an error has been detected in the description of the operation manual for the control panel PU-27.
The following description error has been found in all operation manuals for the PU-27 control panel, page 32, section Ventilation, Ventilation mode setting.
Description error version:
Ventilation
Ventilation mode ON setting
- Ventilation mode OFF. When the heater switches to standby mode, the air pump will shut off.
✓ Ventilation mode ON. When the heater switches to standby mode, the air pump will continue to operate in ventilation mode.
Corrected version:
Ventilation
Ventilation mode ON setting
- Ventilation mode OFF. Heater will maintain set temperature by reducing the heating power, without shutting off the combustion process.
✓ Ventilation mode ON. Heater will operate till the temperature is reached 1°C above the set temperature, shut off the combustion process and start to ventilate till the temperature drops 5°C below the set temperature. When temperature drops, heating starts again
This description error can be found in all operation manuals up to PU-27 operation manual version v.09.19. Page number may differ depending from operation manual language or print layout.
Corrected version of the PU-27 control panel operation manual can be found on www.autoterm.com website.
Corrected description information will be included already in the next shipment.